검색
검색 팝업 닫기

Ex) Article Title, Author, Keywords

Article

Original Article

Korean Journal of Medical Physics 2008; 19(4): 276-284

Published online December 25, 2008

Copyright © Korean Society of Medical Physics.

Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries

외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사

Geon-Ho Jahng*, Dal Mo Yang*, Dong-Wook Sung, Kwang Yong Lee, Hyeog Ju Kim

장건호*ㆍ양달모*ㆍ성동욱ㆍ이광용ㆍ김혁주

*Department of Radiology, East-West Neo Medical Center, Kyung Hee University,Department of Radiology, Kyung Hee Medical Center, Kyung Hee University,Radiation Safety Division, Korea Food and Drug Administration (KFDA), Seoul, Korea

*경희대학교 의과대학 동서신의학병원 영상의학교실, 경희대학교 의과대학 경희의료원 영상의학교실, 식품의약품안전청 방사선 안전과(KFDA, Radiation Safety Division)

Abstract

A computed tomography (CT) is a powerful system for the effectively fast and accurate diagnosis. The CT system, therefore, has used substantially and developed for improving the performance over the past decade, resulting in growing concerns over the radiation dose from the CT. Advanced CT techniques, such as a multidetector row CT scanner and dual energy or dual source CT, have led to new clinical applications that could result in further increases of radiation does for both patients and workers. The objective of this study was to review the international guidelines of the shielding requirements for a CT facility required for a new installation or when modifying an existing one. We used Google Search Engine to search the following keywords: computed tomography, CT regulation or shield or protection, dual energy or dual source CT, multidetector CT, CT radiation protection, and regulatory or legislation or regulation CT. In addition, we searched some special websites, that were provided for sources of radiation protection, shielding, and regulation, RSNA, AAPM, FDA, NIH, RCR, ICRP, IRPA, ICRP, IAEA, WHO (See in Table 1 for full explanations of the abbreviations). We finally summarized results of the investigated materials for each country. The shielding requirement of the CT room design was very well documented in the countries of Canada, United States of America, and United Kingdom. The wall thickness of the CT room could be obtained by the iso-exposure contour or the point source method. Most of documents provided by international organizations were explained in importance of radiation reduction in patients and workers. However, there were no directly-related documents of shielding and patient exposure dose for the dual energy CT system. Based international guidelines, the guideline of the CT room shielding and radiation reduction in patients and workers should be specified for all kinds of CT systems, included in the dual energy CT. We proposed some possible strategies in this paper.

KeywordsComputed tomography, Multidetector row CT, Dual energy CT, Radiation shielding and protection, Patient radiation dose