Progress in Medical Physics 2024; 35(4): 205-213
Published online December 31, 2024
https://doi.org/10.14316/pmp.2024.35.4.205
Copyright © Korean Society of Medical Physics.
Wonyoung Cho1 , Gyu Sang Yoo2
, Won Dong Kim2
, Yerim Kim1
, Jin Sung Kim1,3
, Byung Jun Min2
Correspondence to:Byung Jun Min
(bjmin@cbnuh.or.kr)
Tel: 82-43-269-7498
Fax: 82-43-269-6210
Jin Sung Kim
(jinsung@yuhs.ac)
Tel: 82-2-2228-8118
Fax: 82-2-2227-7823
This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Purpose: This study explores the potential of artificial intelligence (AI) in optimizing radiotherapy protocols for personalized cancer treatment. Specifically, it investigates the role of AI-based segmentation tools in improving accuracy and efficiency across various anatomical regions.
Methods: A dataset of 500 anonymized patient computed tomography scans from Chungbuk National University Hospital was used to develop and validate AI models for segmenting organs-atrisk. The models were tailored for five anatomical regions: head and neck, chest, abdomen, breast, and pelvis. Performance was evaluated using Dice Similarity Coefficient (DSC), Mean Surface Distance, and the 95th Percentile Hausdorff Distance (HD95).
Results: The AI models achieved high segmentation accuracy for large, well-defined structures such as the brain, lungs, and liver, with DSC values exceeding 0.95 in many cases. However, challenges were observed for smaller or complex structures, including the optic chiasm and rectum, with instances of segmentation failure and infinity values for HD95. These findings highlight the variability in performance depending on anatomical complexity and structure size.
Conclusions: AI-based segmentation tools demonstrate significant potential to streamline radiotherapy workflows, reduce inter-observer variability, and enhance treatment accuracy. Despite challenges with smaller structures, the integration of AI enables dynamic, patient-specific adaptations to anatomical changes, contributing to more precise and effective cancer treatments. Future work should focus on refining models for anatomically complex structures and validating these methods in diverse clinical settings.
KeywordsAI-driven segmentation, Personalized cancer treatment, Adaptive radiotherapy, Transfer learning