Korean Journal of Medical Physics 2013; 24(3): 176-182
Published online September 30, 2013
Copyright © Korean Society of Medical Physics.
Jeong-Kyu Park*, Sung Kyu Kim†, Ihn-Ho Cho‡, Eun-Jung Kong‡, Myeong-Hwan Park*, Bok-Yeon Cho§
박정규*ㆍ김성규†ㆍ조인호‡ㆍ공은정‡ㆍ박명환*ㆍ조복연§
Through this research, we measure the data for several SUVs such as SUVLBM, SUVBW, and SUVBSA using volume of interest in order to enhance the diagnostic level in whole-body image for healthy examinees via F-18 FDG PET/CT. Maximum value, mean value, standard deviation, and threshold value for each SUVs are shown. The measurement of SUVs are carried out with 31 examinees who have taken whole-body examination with F-18 FDG PET/CT from July, 2012 to August, 2012. To secure the preciseness of measurement, we selected 26 healthy examinees as a subject of measurement according to diagnostic view of a nuclear-medical doctor. We see from the measurement of SUVs of PET/CT that the value of SUVBW is hightest and followed by SUVLBM and SUVBSA in turn regardless of the use of contrast media. By comparing the SUVLBM-maximum data for the group used contrast media with those for the group used no contrast media, there found a trend that the measured values increase when the contrast media are used. Among them, liver, aorta, lumbar-5, and Cerebellum exhibit significant difference (p<0.05). We conclude that our data for SUVs would be basic references in overall image interpretation, and hope that the research using VOI would be active.
KeywordsF-18 FDG PET/CT, VOI, SUVs, Contrast media